On-load tap changer for capacity and voltage regulation
Category:
Service Hotline:+86-576-83379018
Online Inquiry
Product Details
On-load tap changer for capacity and voltage regulation
On-load tap-changer for capacity and voltage regulation
This switch is suitable for three-phase oil-immersed on‑load tap changers and capacity‑adjustable distribution transformers with a rated voltage of 10 kV AC at 50 Hz or 60 Hz, and a maximum rating ranging from 160 (50) kVA to 630 (200) kVA (hereinafter referred to as “capacity‑and‑voltage‑adjustable transformers”). Under load, the switch can automatically perform capacity adjustment or voltage regulation in response to signals issued by its built-in controller, thereby enabling fine‑tuning of the transformer’s capacity and output voltage, improving power supply quality, and reducing losses.
The switch is applicable to three-phase oil-immersed on-load capacity and voltage regulation distribution transformer (hereinafter referred to as capacity and voltage regulation transformer) with AC 10kV, 50Hz or 60Hz and maximum rated capacity of 160 (50) KVA to 630 (200) kVA. Under the condition that the capacity and voltage regulation transformer is on-load, the automatic capacity regulate or voltage regulation switching can be carried out respectively according to the signals sent by the switch controller (with the switch itself), SO as to adjust the capacity and output voltage of the capacity and voltage regulation transformer, to improve the power quality and reduce the loss of the capacity and voltage regulation transformer.
Meaning of Switch Model Numbers
Type of on-load tap-changer

Basic Performance Parameters of the Switch
Basic performance parameters of tap-changer
1. Equipment maximum voltage: 12 kV Highest voltage of the device: 12 kV
2. Rated maximum current: SYTXZ315(100)/12, 30 A at high voltage and 500 A at low voltage; SYTXZ630(200)/12, 30 A at high voltage and 900 A at low voltage.
Max rate through current: SYTXZ315(100)/12, HV 30A, LV 500A; SYTXZ630(200)/12, HV 30A, LV 900A
3. Capacity regulation method: HV (star-delta switching), LV (series-parallel connection)
4. Switch maximum “step” voltage: capacity regulation 6000V, voltage regulation 300V Max step voltage:capacity regulation 6000V,voltage regulation 300V
5. Number of max voltage regulation operation position: 5 position
Switch appearance and mounting dimensions
Overall and installation dimension


Switch wiring schematic
wiring diagram

Keywords:
On-load tap changer for capacity and voltage regulation
Learn more about the product
Submit your request or feedback
If you are interested in our products, please feel free to contact us to discuss potential collaboration.
Telephone
Email box
Address
No. 3 Fengming Road, Hairun Subdistrict, Sanmen County, Taizhou City, Zhejiang Province
Website Development:China Enterprise Dynamics Nantong|Tag