F-Series On-Load Tap Changer (with Oil Filtration)
F-Series On-Load Tap Changer (with Oil Filtration)
F-Series On-Load Tap Changer (with Oil Filtration)
F-Series On-Load Tap Changer (with Oil Filtration)
F-Series On-Load Tap Changer (with Oil Filtration)
F-Series On-Load Tap Changer (with Oil Filtration)
+
  • F-Series On-Load Tap Changer (with Oil Filtration)
  • F-Series On-Load Tap Changer (with Oil Filtration)
  • F-Series On-Load Tap Changer (with Oil Filtration)
  • F-Series On-Load Tap Changer (with Oil Filtration)
  • F-Series On-Load Tap Changer (with Oil Filtration)
  • F-Series On-Load Tap Changer (with Oil Filtration)

F-Series On-Load Tap Changer (with Oil Filtration)


Service Hotline:+86-576-83379018

product Online Inquiry

Product Details


F-series on-load tap changer
F Series on-load Tap-changer

On-load tap changers feature an advanced design, reliable operation, long service life, and convenient maintenance, making them suitable for three-phase oil-immersed transformers with a rated frequency of 50 Hz, a maximum operating voltage of 40.5 kV or lower, and a rated current of 400 A or less.
This kind of on-load tap-changer has the merits of advanced structure, operating reliably, long useful life and maintenance freely, It is suitable for oil-immersed three-phases transformer with frequency 50Hz, Highest voltage for equipment 40.5KV and below and rated current under 400A and below.

 

Meaning of On-Load Tap-Changer Model Designations
Type of on-load tap-changer

 

 


 

Schematic diagram of the voltage regulation principle for on-load tap changers
On-load tap-changer schematic diagram for voltage regulation

 

 

Installation dimensions of the on-load tap changer controller
On-load tap-changer controller installation size

 

 


 

12kV On-Load Tap Changer Outline Installation Drawing
Overall and installation drawing for 12kV on-load tap-changer

 

 


 

Installation Drawing for 12 kV On-Load Tap Changer: Terminal Voltage Regulation and Mid-Tap Bridging Configuration
Overall and installation drawing for 12kV line terminal voltage regulation on-load tap-changer

 

 


 

Installation drawing of the neutral-point voltage regulator for a 12 kV (rated voltage 1000 V) on-load tap changer.
Overall diagram for 12kV(Step Voltage 1,000V) Neutral point regulation on-load tap-changer

 


 

A switch model designation with the letter “A” indicates that the switch’s maximum voltage rating is 1000 V.
Vo A-stand for the max. step voltage is 1000 V

 


 

Installation drawing of the on-load tap changer terminal for 12 kV (rated voltage 1000 V) with external adjustment.
Overall and installation drawing for 12kV line terminal voltage regulation on-load tap-changer

 


 

1. A switch model designation with the letter “A” indicates that the switch’s maximum rated voltage is 1000 V.
2. The cable for the 10 kV on-load tap changer controller is 15 m long.
1.A-stand for the max. step voltage is 1000 V:
2.The length of the cable for 1 0kV on-load tap-changer is 15 Meters

 


 

On-load tap changer for arc-suppression coils
The on-load tap-changer are applicable to arc suppression coil

 

Rated current of 200 A and below. Maximum equipment voltage: 12 kV, 40.5 kV. Number of tap positions: 7 to 14 levels.
Its rated current is 200A and below, the highest voltage of equipment is 12kV and 40.5kV, numbe fo the operation
position 7-14.
 

FJ 1, -125--200112-15140A

 

 

FJ 11-125-y200/40.5-15140A
 

 

FD III 1 -400/10-10090 on-load tap changer
FD III 1 -400/10-10090 On-load tap-changer

 

 


 

Unified Design of the Outline and Installation Drawing for a 40.5 kV On-Load Tap Changer
Overall and installation drawing for 40.5kV on-load tap-changer in uniform design

 

40.5 kV on-load tap changer controller cable, 20 m long

The length of the cable for 40.5kV on-load tap-changer is 20 Meters

Keywords:

F-Series On-Load Tap Changer (with Oil Filtration)

Learn more about the product

Submit your request or feedback

If you are interested in our products, please feel free to contact us to discuss potential collaboration.