Non‑excited tubular and drum‑type tap changers (WDG series, WDG+WLG series, WSG series) are rated for voltages of 110 kV or less (with a maximum equipment voltage of 126 kV) and rated currents of 4,000 A or less. They offer three‑phase interlocked operation, 1+2‑phase operation, and single‑phase operation, with actuation methods including direct operation from the tank cover or bottom, side‑wall mounting, or interlocked operation.

Three-phases linear voltage-regulating(I、)pipe-form (G)vertical tap-changer(250~800A)

Type of tap-changer and installation size chart

Switch model
Type of tap-changer
Rated Current (A)
Rated current
Maximum Voltage (kV)
Highest voltage
Number of tap positions
Tap position number
Installation dimensions (mm)
Install dimension (mm)
H H1 H2 H3 Φd1 Φd2
WSG | 250–630/40.5 – 3 × 3
WSG | 250–630/40.5 – 5 × 5
WSG | △ 250–630/40.5 – 3 × 3
WSG | △ 250–630/40.5 – 5 × 5
250 
400 
500 
630
40.5 3, 5 250 260 950 1050 170 186
WSG | 250–630/40.5 – 7 × 7
WSG | △ 250–630/40.5 – 7 × 7
7 220 237
WSG | 250–630/72.5-126 – 3 × 3
WSG | 250–630/72.5-126 – 5 × 5
72.5, 126 3, 5 300 260 1050 1250 190 207
WSG | 800/40.5 – 3 × 3
WSG | 800/40.5 – 5 × 5
WSG | △ 800/40.5 – 3 × 3
WSG | △ 800/40.5 – 5 × 5
800 40.5 350 265 1200 1300 170 186
WSG | 800/40.5 – 7 × 7
WSG | △ 800/40.5 – 7 × 7
7 220 237

1. The phase sequence of the switch is determined by the user;

2. When selecting a surface‑mount installation, please add the letter “E” after the switch model number to distinguish it.

1. The selection of phases are upon the customer's requests.

2. When the customers choose the Floor-form fixing mode, please add the suffix E as a mark.

Three-phases linear voltage-regulating (I、 I )pipe-form(G)vertical tap-changer

Type of tap-changer and installation size chart

Switch model
Type of tap-changer
Rated Current (A)
Rated current
Maximum Voltage (kV)
Highest voltage
Number of tap positions
Tap position number
Installation dimension (mm)
H H1 H2 H3 H4 H5 Φd Φd1 Φd2  
WSG | 1000/40.5 – 3 × 3
WSG | 1000/40.5 – 5 × 5
WSG | △ 1000/40.5 – 3 × 3
WSG | △ 1000/40.5 – 5 × 5
1000 40.5 3, 5 350 265 75 35 1200 1300 18 170 186  
WSG | 1000/40.5 – 7 × 7
WSG | △ 1000/40.5 – 7 × 7
7 220 237  
WSG | 1250/40.5 – 3 × 3
WSG | 1250/40.5 – 5 × 5
WSG | △ 1250/40.5 – 3 × 3
WSG | △ 1250/40.5 – 5 × 5
1250 3, 5 400 300 75 60 1400 1500 22 190 207  
WSG | 1600/40.5 – 3 × 3
WSG | 1600/40.5 – 5 × 5
WSG | △ 1600/40.5 – 3 × 3
WSG | △ 1600/40.5 – 5 × 5
1600 210 227  
WSG | 2000/40.5 – 3 × 3
WSG | 2000/40.5 – 5 × 5
WSG | △ 2000/40.5 – 3 × 3
WSG | △ 2000/40.5 – 5 × 5
2000 250 267  

1. The phase sequence of the switch is determined by the user;
2. When selecting a surface‑mount installation, please add the letter “E” after the switch model number to distinguish it.
1. The selection of phases are upon the customer's requests.
2. When the customers choose the Floor-form fixing mode, please add the suffix E as a mark.

1+2-phase vertical linear voltage-regulating (I, |) pipe-form (G) tap-changer (250~800A) "1+2" phases linear voltage-regulating (I, I) pipe-form (G) vertical tap-changer

Type of tap-changer and installation size chart

Switch model Type of tap-changer Rated current (A) Highest voltage (kV) Tap position number Installation dimensions (mm) Install dimension (mm)  
H H1 H2 Φd1 Φd2  
WDG | 250–630/40.5 – 3 × 3
WDG | 250–630/40.5 – 5 × 5
WDG | △ 250–630/40.5 – 3 × 3
WDG | △ 250–630/40.5 – 5 × 5
250
400
500
630
40.5 3, 5 — 260 610 170 186  
WLG | 250–630/40.5 – 3 × 3
WLG | 250–630/40.5 – 5 × 5
WLG | △ 250–630/40.5 – 3 × 3
WLG | △ 250–630/40.5 – 5 × 5
250 260 700  
WDG | 250–630/40.5 – 7 × 7
WDG | △ 250–630/40.5 – 7 × 7
7 — 260 610 220 237  
WLG | 250–630/40.5 – 7 × 7
WLG | △ 250–630/40.5 – 7 × 7
250 260 700  
WDG | 250–630/72.5–126 – 3 × 3
WDG | 250–630/72.5–126 – 5 × 5
72.5, 126 3, 5 — 300 680 190 207
WLG | 250–630/72.5–126 – 3 × 3
WLG | 250–630/72.5–126 – 5 × 5
400 260 900      
WDG | 800/40.5 – 3 × 3
WDG | 800/40.5 – 5 × 5
WDG | △ 800/40.5 – 3 × 3
WDG | △ 800/40.5 – 5 × 5
800 40.5 — 265 610 170 186
WLG | 800/40.5 – 3 × 3
WLG | 800/40.5 – 5 × 5
WLG | △ 800/40.5 – 3 × 3
WLG | △ 800/40.5 – 5 × 5
350 265 900      

1+2-phase vertical linear voltage-regulating (I, I) pipe-form (G) tap-changer (1000~2000A) "1+2" Phases linear voltage-regulating(I、I )pipe-form (G)vertical tap-changer

Type of tap-changer and installation size chart

Switch model
Type of tap-changer
Rated Current (A)
Rated current
Maximum Voltage (kV)
Highest voltage
Number of tap positions
Tap position number
Installation dimensions (mm)
Install dimension (mm)
H H1 H2 H3 H4 Φd Φd1 Φd2
WDG | 1000/40.5 – 3 × 3
WDG | 1000/40.5 – 5 × 5
WDG | △ 1000/40.5 – 3 × 3
WDG | △ 1000/40.5 – 5 × 5
1000 40.5 3, 5 — 265 75 35 610 18 170 186
WLG | 1000/40.5 – 3 × 3
WLG | 1000/40.5 – 5 × 5
WLG | △ 1000/40.5 – 3 × 3
WLG | △ 1000/40.5 – 5 × 5
350 265 75 35 900 18
WDG | 1000/40.5 – 7 × 7
WDG | △ 1000/40.5 – 7 × 7
7 — 265 75 35 610 18 220 237
WLG | 1000/40.5 – 7 × 7
WLG | △ 1000/40.5 – 7 × 7
350 265 75 35 900 18
WDG | 1250/40.5 – 3 × 3
WDG | 1250/40.5 – 5 × 5
1250 3, 5 — 340 75 60 680 22 190 207
WLG | 1250/40.5 – 3 × 3
WLG | 1250/40.5 – 5 × 5
400 300 75 60 1000 22
WDG | 1600/40.5 – 3 × 3
WDG | 1600/40.5 – 5 × 5
1600 — 340 75 60 680 22 210 227
WLG | 1600/40.5 – 3 × 3
WLG | 1600/40.5 – 5 × 5
400 300 75 60 1000 22
WDG | 2000/40.5 – 3 × 3
WDG | 2000/40.5 – 5 × 5
2000 — 340 75 60 680 22 250 267
WLG | 2000/40.5 – 3 × 3
WLG | 2000/40.5 – 5 × 5
400 300 75 60 1000 22

Three-phases linkage single-bridge crossing connection(Il )pipe-form (G)verticaltap-changer

Type of tap-changer and installation size chart

Switch model
Type of tap-changer
Rated Current (A)
Rated current
Maximum Voltage (kV)
Highest voltage
Number of tap positions
Tap position number
Installation dimensions (mm) Install dimension (mm)
H H1 H2 H3 Φd1 Φd2  
WSG II 250~800/40.5 - 4×3
WSG II 250~800/40.5 - 6×5
250
400
500
630
800
40.5 3, 5 250 225 950 1050 170 186  
WSG II 250~800/40.5 - 8×7 7 250 225 950 1050  
WSG II 250~800/126 - 4×3
WSG II 250~800/126 - 6×5
126 3, 5 375 245 1200 1500  
WSG II 250~800/126 - 8×7 7 375 245 1200 1500 210 227  

1. The phase sequence of the switch is determined by the user;
2. When selecting a surface‑mount installation, please add the letter “E” after the switch model number to distinguish it.
1. The selection of phases are upon the customer s requests.
2. When the customer chooses the floor-form fixing mode, please add the suffix "E" as a mark.

Three-phases linkage single-bridge crossing connection( Il )pipe-form (G)verticaltap-changer

Type of tap-changer and installation size chart

Switch model Type of tap-changer Rated current (A) Highest voltage (kV) Tap position number Installation dimensions (mm) Install dimension (mm)
H H1 H2 H3 H4 H5 Φd Φd1 Φd2  
WSG II 1000/40.5 – 4×3
WSG Ⅱ 1000/40.5 – 6×5
WSG Ⅱ 1000/40.5 – 8×7
1000 40.5 3, 5, 7 350 300 150 35 1250 1350 18 170 186  
WSG Ⅱ 1000/126 – 4×3
WSG II 1000/126 – 6×5
126 3, 5 550 1650 1900  
WSG II 1250~2000/40.5 – 4×3
WSG II 1250~2000/40.5 – 6×5
WSG II 1250~2000/40.5 – 8×7
1250
1600
2000
40.5 3, 5, 7 450 60 1500 1650 22 190 207  
WSG II 1250~2000/126 – 4×3
WSG II 1250~2000/126 – 6×5
126 3, 5 550 1700 –  

1. The phase sequence of the switch is determined by the user;
2. When selecting a surface‑mount installation, please add the letter “E” after the switch model number to distinguish it.
1. The selection of phases are upon the customer 's requests.
2. When the customer chooses the floor-form fixing mode, please add the suffix "E" as a mark.

"1+2" phase linkage single-bridge crossing connection (Il) pipe-form (G) vertical tap-changer (250~800A)

Type of tap-changer and installation size chart

Switch model
Type of tap changer
Rated Current (A)
Rated current
Maximum Voltage (kV)
Highest voltage
Number of tap positions
Tap position number
Installation dimensions (mm) Install dimension (mm)
H H1 H2 Φd1 Φd2
WDG II 250~800/40.5 – 4 × 3
WDG II 250~800/40.5 – 6 × 5
250, 400, 500, 630, 800 40.5 3, 5 — 305 610 170 186
WLG II 250~800/40.5 – 4 × 3
WLG II 250~800/40.5 – 6 × 5
250 225 700
WDG II 250~800/40.5 – 8 × 7 7 — 305 610
WLG II 250~800/40.5 – 8 × 7 250 225 700
WDG II 250~800/126 – 4 × 3
WDG II 250~800/126 – 6 × 5
126 3, 5 — 305 610
WLG II 250~800/126 – 4 × 3
WLG II 250~800/126 – 6 × 5
450 245 900
WDG II 250~800/126 – 8 × 7 7 — 305 610 210 227
WLG II 250~800/126 – 8 × 7 450 245 900

1. The phase sequence of the switch is determined by the user;
2. When selecting a surface‑mount installation, please add the letter “E” after the switch model number to distinguish it.
1. The selection of phases are upon the customer's requests.
2. When the customer chooses the floor-form fixing mode, please add the suffix "E" as a mark.

"1+2" phase linkage single-bridge crossing connection (Il) pipe-form (G) vertical tap-changer (1000~2000A) "1+2" phase linkage single-bridge crossing connection (Il) pipe-form (G) vertical tap-changer

Type of tap-changer and installation size chart

Switch model
Type of tap-changer
Rated Current (A)
Rated current
Maximum Voltage (kV)
Highest voltage
Number of tap positions
Tap position number
Installation dimension (mm)
H H1 H2 H3 H4 Φd Φd1 Φd2  
WDG II 1000/40.5 – 4×3
WDG II 1000/40.5 – 6×5
WDG II 1000/40.5 – 8×7
1000 40.5 3, 5, 7 – – – 35 – 18 170 186  
WLG II 1000/40.5 – 4×3
WLG II 1000/40.5 – 6×5
WLG II 1000/40.5 – 8×7
350 300 150 900  
WDG II 1000/126 – 4×3
WDG II 1000/126 – 6×5
126 3, 5 – – – –  
WLG II 1000/126 – 4×3
WLG II 1000/126 – 6×5
550 300 150 1100  
WDG II 1250~2000/40.5 – 4×3
WDG II 1250~2000/40.5 – 6×5
WDG II 1250~2000/40.5 – 8×7
1250
1600
2000
40.5 3, 5, 7 – – – 60 – 22 190 207  
WLG II 1250~2000/40.5 – 4×3
WLG II 1250~2000/40.5 – 6×5
WLG II 1250~2000/40.5 – 8×7
450 300 150 1050  
WDG II 1250~2000/126 – 4×3
WDG II 1250~2000/126 – 6×5
126 3, 5 – – – –  
WLG II 1250~2000/126 – 4×3
WLG II 1250~2000/126 – 6×5
550 300 150 1150  

1. The phase sequence of the switch is determined by the user;
2. When selecting a surface‑mount installation, please add the letter “E” after the switch model number to distinguish it.
1. The selection of phases are upon the customer's requests.
2. When the customer chooses the floor-form fixing mode, please add the suffix "E" as a mark.

Three-phases linkage single-bridge crossing connection ( Il ) pipe-form (G)horizontal tap-changer

Type of tap-changer and installation size chart

Switch model
Type of tap-changer
Rated current
(A)
Rated current
Maximum voltage
(kV)
Highest voltage
Number of tap positions
Tap position number
Installation dimensions (mm) Install dimension (mm)
L L1 L2 L3 L4 B H H1 Φd1 Φd2  
WSG II 250~800/40.5 - 4×3W
WSG II 250~800/40.5 - 6×5W
250-800 40.5 3, 5 250 225 950 455 465 250 200 350 170 186  
WSG II 250~800/40.5 - 8×7W 7 250 225 950 455 465 200 350  
WSG II 250~800/72.5 - 6×5W 72.5 3, 5 350 295 1200 575 715 280 430  

1. The phase sequence of the switch is determined by the user.
1. The selection of phases are upon the customer 's requests.

Three-phases vertical y - exchanger (IV)pipe (G)tap-changer

 

Type of tap-changer and installation size chart

Switch model
Type of tap changer
Rated Current (A)
Rated current
Maximum Voltage (kV)
Highest voltage
Number of tap positions
Tap position number
Installation dimensions (mm)
Install dimension (mm)
H H1 H2 Φd1 Φd2  
WSG IV 250–630/12 – 3×2 250-630 12 2 240 245 950 190 207  
WSG IV 800–1000/12 – 3×2 800-1000 350 265 1200  
WSG IV 1250/12 – 3×2 1250 350 295 1300 190 207  
WSG IV 1600/12 – 3×2 1600 210 227  
WSG IV 2000/12 – 3×2 2000 350 300 1300 250 267  

1. The phase sequence of the switch is determined by the user;
2. When selecting a surface‑mount installation, please add the letter “E” after the switch model number to distinguish it.
1. The selection of phases are upon the customer 's requests.
2. When the customer chooses the floor-form fixing mode, please add the suffix "E" as a mark.

Three-phases double-bridge crossing connection(V)pipe-form (G)vertical tap-changer

Type of tap-changer and installation size chart

Switch model
Type of tap-changer
Rated Current (A)
Rated current
Maximum Voltage (kV)
Highest voltage
Number of tap positions
Tap position number
Installation dimensions (mm) Install dimension (mm)
H H1 H2 H3 H4 Φd1 Φd2
WSG V 250–800/12 – 4×3
WSG V 250–800/12 – 6×5
250–800 12 3, 5 200 225 200 1400 1400 170 186
WSG V 250–800/40.5 – 4×3
WSG V 250–800/40.5 – 6×5
40.5 250 225 200 1550 1650
WSG V 250–800/12 – 8×7 12 7 200 225 200 1400 1400
WSG V 250–800/40.5 – 8×7 40.5 250 225 200 1550 1650

1. The phase sequence of the switch is determined by the user;
2. When selecting a surface‑mount installation, please add the letter “E” after the switch model number to distinguish it.
1. The selection of phases are upon the customer's requests.
2. When the customer chooses the floor-form fixing mode, please add the suffix "E" as a mark.

Keywords:

Non-excitation tap changer

Learn more about the product

Submit your request or feedback

If you are interested in our products, please feel free to contact us to discuss potential collaboration.