WST4 Series Strip-Type No-Excitation Tap Changer
Category:
Service Hotline:+86-576-83379018
Online Inquiry
Product Details
This type of switch operating mechanism comes in two variants, as follows; unless otherwise specified, the switch is equipped with Type B.
WSTI4T Series bar-form de-energized tap-changer
Type of tap-changer and installation size chart
| Switch model Type of tap changer |
Installation dimension (mm) | Hatch opening Holes on tank cover (mm) |
|||||
| H | L | L1 | l | Φd1 | Φd2 | ||
| WSTⅠ,30/24-4×3T | 70, 100, 150, 170, 200 (For user selection) |
405 | 65 | 18 | Φ3.1 | Φ5 | Φ20*1 |
| WSTⅠ,30/24-6×5T | 513 | ||||||
| WSTⅠ,30/24-8×7T | 621 | ||||||
| WSTⅠ,30/33-4×3T | 480 | 90 | |||||
| WSTⅠ,30/33-6×5T | 588 | ||||||
| WSTⅠ,30/33-6×5T | 696 | ||||||
| WSTⅠ,63/24-4×3T | 405 | 65 | Φ5.1 | Φ7 | |||
| WSTⅠ,63/24-6×5T | 513 | ||||||
| WSTⅠ,63/24-8×7T | 621 | ||||||
| WSTⅠ,63/33-4×3T | 480 | 90 | |||||
| WSTⅠ,63/33-6×5T | 588 | ||||||
| WSTⅠ,63/33-8×7T | 696 | ||||||
Post-processing of this structural switch model
The operating mechanism of the tap changer is available in plastic and aluminum alloy, offering users a choice.
Add T to the type of this kind of tap-changer
Available materials of the tap-changer knob for the users to choose are plastic and aluminum alloy.
WSTIIT Series bar-form de-energized tap-changer
| Switch model Type of tap changer |
Installation dimension (mm) | Hatch opening Holes on tank cover(mm) |
|||||
| H | L | L1 | l | Φd1 | Φd2 | ||
| WST II4 30/24-4 × 3T | 70, 100, 150, 170, 200 (According to user selection) |
347 | 55 | 18 | Φ3.1 | Φ5 | Φ20+1 |
| WST II4 30/24-6 × 5T | 455 | ||||||
| WST II4 30/24-8 × 7T | 563 | ||||||
| WST II4 30/33-4 × 3T | 422 | 80 | |||||
| WST II4 30/33-6 × 5T | 530 | ||||||
| WST II4 30/33-8 × 7T | 638 | ||||||
| WST II4 63/24-4 × 3T | 347 | 55 | Φ5.1 | Φ7 | |||
| WST II4 63/24-6 × 5T | 455 | ||||||
| WST II4 63/24-8 × 7T | 563 | ||||||
| WST II4 63/33-4 × 3T | 422 | 80 | |||||
| WST II4 63/33-6 × 5T | 530 | ||||||
| WST II4 63/33-8 × 7T | 638 | ||||||
This structural switch model is designated with a trailing “T”.
The operating mechanism of the tap changer is available in plastic and aluminum alloy, offering users a choice.
Add T to the type of this kind of tap-changer
Available materials of the tap-changer knob for the users to choose are plastic and aluminum alloy.
WSTIII4 T Series bar-form de-energized tap-changer
Type of tap-changer and installation size chart
| Switch model Type of tap changer |
Installation dimension (mm) | Hatch opening Holes on tank cover (mm) |
|||||
| H | L | L1 | l | Φd1 | Φd2 | ||
| WDTⅡ430/24-4×3T | 70, 100, 150, 170, 200 (For user selection) |
182 | 55 | 18 | Φ3.1 | Φ5 | Φ20+1 |
| WDTⅡ430/24-6×5T | 250 | ||||||
| WDTⅡ430/24-8×7T | 323 | ||||||
| WDTⅡ430/33-4×3T | 207 | 80 | |||||
| WDTⅡ430/33-6×5T | 275 | ||||||
| WDTⅡ430/33-8×7T | 348 | ||||||
| WDTⅡ463/24-4×3T | 182 | 55 | Φ5.1 | Φ7 | |||
| WDTⅡ463/24-6×5T | 250 | ||||||
| WDTⅡ463/24-8×7T | 323 | ||||||
| WDTⅡ463/33-4×3T | 207 | 80 | |||||
| WDTⅡ463/33-6×5T | 275 | ||||||
| WDTⅡ463/33-8×7T | 348 | ||||||
WDTIIT series bar-form de-energized tap-changer
Type of tap-changer and installation size chart
| Switch model Type of tap changer |
Installation dimension (mm) | Hatch opening Holes on tank cover(mm) |
|||||
| H | L | L1 | l | Φd1 | ϕd2 | ||
| WST Ⅲ ₄ 30/24–3 × 3T | 70, 100, 150, 170, 200 (For user selection) |
302 | 40 | 18 | Φ3.1 | Φ5 | Φ20*1 |
| WST Ⅲ ₄ 30/24–5 × 5T | 410 | ||||||
| WST Ⅲ ₄ 30/24–7 × 7T | 518 | ||||||
| WST Ⅲ ₄ 30/33–3 × 3T | 422 | 80 | |||||
| WST Ⅲ ₄ 30/33–5 × 5T | 530 | ||||||
| WST Ⅲ ₄ 30/33–7 × 7T | 638 | ||||||
| WST Ⅲ ₄ 63/24–3 × 3T | 302 | 40 | Φ5.1 | Φ7 | |||
| WST Ⅲ ₄ 63/24–5 × 5T | 410 | ||||||
| WST Ⅲ ₄ 63/24–7 × 7T | 518 | ||||||
| WST Ⅲ ₄ 63/33–3 × 3T | 422 | 80 | |||||
| WST Ⅲ ₄ 63/33–5 × 5T | 530 | ||||||
| WST Ⅲ ₄ 63/33–7 × 7T | 638 | ||||||
W(D+L)TII4 T Series bar-form de-energized tap-changer
W(D+L)Tll4.30~63/12-6x5T (Forward)
Type of tap-changer and installation size chart
| Switch model Type of tap-changer |
Installation dimension (mm) | Hatch opening Holes on tank cover (mm) |
||||
| H | L | L1 | Φd1 | Φd2 | ||
| WST II 41 30/12~24-4 × 3T | 70, 100, 120, 150, 170, 200 | 347 | 55 | 3.1 | 5 | Φ43 |
| WST II 41 63/12~24-4 × 3T | 347 | 55 | 5.1 | 7 | Φ43 | |
| WST II 41 30/12~24-6 × 5T | 455 | 55 | 3.1 | 5 | Φ43 | |
| WST II 41 63/12~24-6 × 5T | 455 | 55 | 5.1 | 7 | Φ43 | |
| WST II 41 30/12~24-8 × 7T | 563 | 55 | 3.1 | 5 | Φ43 | |
| WST II 41 63/12~24-8 × 7T | 563 | 55 | 5.1 | 7 | Φ43 | |
| WST II 41 30/30~33-4 × 3T | 422 | 80 | 3.1 | 5 | Φ43 | |
| WST II 41 63/30~33-4 × 3T | 422 | 80 | 5.1 | 7 | Φ43 | |
| WST II 41 30/30~33-6 × 5T | 530 | 80 | 3.1 | 5 | Φ43 | |
| WST II 41 63/30~33-6 × 5T | 530 | 80 | 5.1 | 7 | Φ43 | |
| WST II 41 30/30~33-8 × 7T | 638 | 80 | 3.1 | 5 | Φ43 | |
| WST II 41 63/30~33-8 × 7T | 638 | 80 | 5.1 | 7 | Φ43 | |
WST II42 T Series bar-form de-energized tap-changer
Type of tap-changer and installation size chart
| Switch model Type of tap-changer |
Installation dimension (mm) | Hatch opening Holes on tank cover (mm) |
||||
| H | L | L1 | Φd1 | Φd2 | ||
| WST II 42 30/12~24-4×3T | 70, 100, 120, 150, 170, 200 | 347 | 55 | 3.1 | 5 | Φ20 |
| WST II 42 63/12~24-4×3T | 347 | 55 | 5.1 | 7 | ||
| WST II 42 30/12~24-6×5T | 455 | 55 | 3.1 | 5 | ||
| WST II 42 63/12~24-6×5T | 455 | 55 | 5.1 | 7 | ||
| WST II 42 30/12~24-8×7T | 563 | 55 | 3.1 | 5 | ||
| WST II 42 63/12~24-8×7T | 563 | 55 | 5.1 | 7 | ||
| WST II 42 30/30~33-4×3T | 422 | 80 | 3.1 | 5 | ||
| WST II 42 63/30~33-4×3T | 422 | 80 | 5.1 | 7 | ||
| WST II 42 30/30~33-6×5T | 530 | 80 | 3.1 | 5 | ||
| WST II 42 63/30~33-6×5T | 530 | 80 | 5.1 | 7 | ||
| WST II 42 30/30~33-8×7T | 638 | 80 | 3.1 | 5 | ||
| WST II 42 63/30~33-8×7T | 638 | 80 | 5.1 | 7 | ||
WSTII44T Series bar-form de-energized tap-changer
Type of tap-changer and installation size chart
| Switch model Type of tap-changer |
Installation dimension (mm) | Hatch opening Holes on tank cover (mm) |
||
| H | L | L1 | ||
| WST Ⅱ 44 63/12-4×3T | 70, 100, 120, 150, 170, 200 | 347 | 55 | Φ20 |
| WST Ⅱ 44 63/12-6×5T | 347 | 55 | Φ20 | |
| WST Ⅱ 44 63/12-8×7T | 455 | 55 | Φ20 | |
WST II4 Series bar-form combined de-energized tap-changer
Type of tap-changer and installation size chart
| Switch model Type of tap-changer |
Installation dimension (mm) | Hatch opening Holes on tank cover (mm) |
||||
| H | L | L1 | Φd1 | Φd2 | ||
| WST Ⅱ 4 30/12~24-4×3T ZH | 70, 100, 120, 150, 170, 200 | 347 | 55 | 3.1 | 5 | Φ20 |
| WST Ⅱ 4 63/12~24-4×3T ZH | 347 | 55 | 5.1 | 7 | ||
| WST Ⅱ 4 30/12~24-6×5T ZH | 455 | 55 | 3.1 | 5 | ||
| WST Ⅱ 4 63/12~24-6×5T ZH | 455 | 55 | 5.1 | 7 | ||
| WST Ⅱ 4 30/12~24-8×7T ZH | 563 | 55 | 3.1 | 5 | ||
| WST Ⅱ 4 63/12~24-8×7T ZH | 563 | 55 | 5.1 | 7 | ||
WSTVI4 30~63/24-5x2T
WSTll4 30~63/24-6 5T
WSTll4 30~63/24-6x5T
Type of tap-changer and installation size chart
| Switch model Type of tap-changer |
Installation dimension (mm) | Hatch opening Holes on tank cover (mm) |
||
| H | Φd1 | Φd2 | ||
| WSTⅥ△30/24-5×2T WSTⅡ△30/24-6×5T WSTⅡ△30/24-6×5T |
70, 100, 200 | 3.1 | 5 | φ20 |
| WSTⅥ△63/24-5×2T WSTⅡ△63/24-6×5T WSTⅡ△63/24-6×5T |
5.1 | 7 | φ20 | |
WSTII4 □/□-□x□ LW series bar-formde-energized tap-changer
Type of tap-changer and installation size chart
| Switch model Type of tap changer |
Installation dimension (mm) | Hatch opening Holes on tank cover (mm) |
||||
| L | L1 | l | Φd1 | Φd2 | ||
| WST II 4 30/10~24-4×3LW | 357 | 55 | 18 | Φ2.5 Φ3.1 Φ5.1 |
Φ5 | Φ20+1 |
| WST II 4 63/10~24-4×3LW | 357 | 55 | 18 | Φ7 | ||
| WST II 4 30/10~24-5×4LW | 401 | 55 | 18 | Φ5 | ||
| WST II 4 63/10~24-5×4LW | 401 | 55 | 18 | Φ7 | ||
| WST II 4 30/10~24-6×5LW | 455 | 55 | 18 | Φ5 | ||
| WST II 4 63/10~24-6×5LW | 455 | 55 | 18 | Φ7 | ||
| WST II 4 30/30~33-6×5LW | 530 | 80 | 18 | Φ5 | ||
| WST II 4 63/30~33-6×5LW | 530 | 80 | 18 | Φ7 | ||
WSTII4 □/□-□x□ LN series bar-form de-energized tap-changer
Type of tap-changer and installation size chart
| Switch model Type of tap changer |
Installation dimension (mm) | Hatch opening Holes on tank cover (mm) |
|||||
| H | L | L1 | l | Φd1 | ϕd2 | ||
| WST Ⅱ ₄ 30/10~24-4×3LN | 108, 158, 208 |
357 | 55 | 18 | Φ2.5 Φ3.1 Φ5.1 |
Φ5 | Φ20+1 |
| WST Ⅱ ₄ 63/10~24-4×3LN | 357 | 55 | 18 | Φ7 | |||
| WST Ⅱ ₄ 30/10~24-5×4LN | 401 | 55 | 18 | Φ5 | |||
| WST Ⅱ ₄ 63/10~24-5×4LN | 401 | 55 | 18 | Φ7 | |||
| WST Ⅱ ₄ 30/10~24-6×5LN | 455 | 55 | 18 | Φ5 | |||
| WST Ⅱ ₄ 63/10~24-6×5LN | 455 | 55 | 18 | Φ7 | |||
| WST Ⅱ ₄ 30/30~33-6×5LN | 530 | 80 | 18 | Φ5 | |||
| WST Ⅱ ₄ 63/30~33-6×5LN | 530 | 80 | 18 | Φ7 | |||
WSTlI4 30~63/35-6x5YK series bar-form de-energized tap-changer
Type of tap-changer and installation size chart
| Switch model Type of tap changer |
Installation dimension (mm) | Hatch opening Holes on tank cover (mm) |
||||
| L | L1 | L2 | Φd1 | Φd2 | ||
| WST Ⅱ 430/35-6×5YK BH8~12 L=1134 | 1134 | 320 | 330 | Φ3.1 | Φ5 | Φ20+1 |
| WST Ⅱ 463/35-6×5YK BH8~12 L=1134 | 1134 | 320 | 330 | Φ5.1 | Φ7 | |
| WST Ⅱ 430/35-6×5YK BH8~12 L=1334 | 1334 | 420 | 430 | Φ3.1 | Φ5 | |
| WST Ⅱ 463/35-6×5YK BH8~12 L=1334 | 1334 | 420 | 430 | Φ5.1 | Φ7 | |
Keywords:
WST4 Series Strip-Type No-Excitation Tap Changer
Learn more about the product
Submit your request or feedback
If you are interested in our products, please feel free to contact us to discuss potential collaboration.
Telephone
Email box
Address
No. 3 Fengming Road, Hairun Subdistrict, Sanmen County, Taizhou City, Zhejiang Province