WSPlI, WSPIIl, Series de-energized Tap-changer (Tray form)
This switch was jointly designed in May 1994 by the Shenyang Transformer Research Institute and several manufacturers at Sanmen Tenglong Electrical Appliance Co., Ltd. It incorporates a novel structure, new materials, and advanced manufacturing processes—specifically, the lower portion of the switch housing has been reduced in height by 50–80 mm—and boasts a well‑thought‑out design, excellent tactile feedback, smooth and flexible operation, precise positioning, superior sealing performance, and low contact resistance. It represents an upgraded, next‑generation product for no‑excitation tap changers in China and received ministerial‑level appraisal in December 1995. Available in both three‑phase and single‑phase versions, it is suitable for oil‑immersed power transformers operating at frequencies of 50 or 60 Hz, with maximum rated voltages of 12 kV, 40.5 kV, or 72.5 kV, and rated currents of 63 A, 125 A, 250 A, or 400 A. The switch can be directly mounted on the transformer tank cover or wall and enables tap changes under no‑excitation conditions.
Type of tap-changer and installation size chart
| Switch model Type of tap-changer |
Rated Current (A) Rated current(A) |
Maximum Equipment Voltage (kV) Highest voltage for equipment (kV) |
Voltage regulation range Range of voltage regulation |
Number of phases Number of phases |
Pressure-regulating section Regulating position |
Installation dimensions (mm) Install dimension (mm) |
Hole diameter on the box lid (ΦD, mm) Holes on tank cover ΦD(mm) |
||||
| H | H1 | ΦD2 | ΦD1 | Md | |||||||
| WDPⅠ,25/24-10×5 | 25 | 24 | ±2×2.5% | 1 | Wire end Line terminal |
159 | 90 | 88 | 145 | M5 | Φ43 |
| WDPⅡ,63/40.5-4×3 | 63 | 40.5 | ±5% | Central region Middle part |
205 | 130 | 88 | 170 | M6 | ||
| WDPⅡ,63/40.5-6×5 | 63 | ±2×2.5% | 205 | 130 | 88 | 170 | M6 | ||||
| WDPⅡ,63/40.5-8×7 | 63 | ±3×2% | 205 | 130 | 88 | 170 | M6 | ||||
| WDPⅡ,63/40.5-10×9 | 63 | ±4×1.25% | 205 | 130 | 88 | 170 | M6 | ||||
| WDPⅡ,125/40.5-4×3 | 125 | ±5% | 205 | 130 | 88 | 170 | M8 | ||||
| WDPⅡ,125/40.5-6×5 | 125 | ±2×2.5% | 205 | 130 | 88 | 170 | M8 | ||||
| WDPⅡ,125/40.5-8×7 | 125 | ±3×2% | 205 | 130 | 88 | 170 | M8 | ||||
| WDPⅡ,125/40.5-10×9 | 125 | ±4×1.25% | 205 | 130 | 88 | 170 | M8 | ||||
| WDPⅡ,125/72.5-10×9 | 125 | 72.5 | ±4×1.25% | 300 | 230 | 88 | 218 | M8 | |||
| WDPⅡ,63/12-4×3 | 63 | 12, 24 | ±5% | 150 | 73 | 77 | 107 | M6 | |||
| WDPⅡ,63/24-4×3 | 63 | ±5% | 170 | 100 | 77 | 120 | M6 | ||||
| WDPⅡ,63/12-6×5 | 63 | ±2×2.5% | 150 | 73 | 77 | 107 | M6 | ||||
| WDPⅡ,63/24-6×5 | 63 | ±2×2.5% | 170 | 100 | 77 | 120 | M6 | ||||
| WDPⅤ,63/12-4×3 | 63 | ±5% | double-bridge crossing connection | 135 | 60 | 77 | 135 | M6 | |||
| WSPⅡ,63/12-4×3 | 63 | ±5% | 3 | Central region Middle part |
150 | 75 | 88 | 170 | M6 | ||
| WSPⅡ,63/24-4×3 | 63 | ±5% | 150 | 75 | 88 | 170 | M6 | ||||
| WSPⅡ,125/12-4×3 | 125 | ±5% | 150 | 75 | 88 | 175 | M8 | ||||
| WSPⅡ,125/24-4×3 | 125 | ±5% | 150 | 75 | 88 | 175 | M8 | ||||
| WSPⅡ,250/12-4×3 | 250 | ±5% | 160 | 85 | 108 | 220 | M8 | ||||
| WSPⅡ,250/24-4×3 | 250 | ±5% | 160 | 85 | 108 | 220 | M8 | ||||
| WSPⅡ,63/12-6×5 | 63 | ±2×2.5% | 150 | 75 | 88 | 197 | M6 | ||||
| WSPⅡ,63/24-6×5 | 63 | ±2×2.5% | 150 | 75 | 88 | 197 | M6 | ||||
| WSPⅡ,125/12-6×5 | 125 | ±2×2.5% | 150 | 75 | 88 | 200 | M8 | ||||
| WSPⅡ,125/24-6×5 | 125 | ±2×2.5% | 150 | 75 | 88 | 200 | M8 | ||||
| WSPⅡ,250/12-6×5 | 250 | ±2×2.5% | 160 | 85 | 108 | 280 | M8 | ||||
| WSPⅡ,250/24-6×5 | 250 | ±2×2.5% | 160 | 85 | 108 | 280 | M8 | ||||
| Switch model Type of tap-changer |
Rated Current (A) Rated current(A) |
Maximum Equipment Voltage (kV) Highest voltage for equipment (kV) |
Voltage regulation range Range of voltage regulation |
Number of phases Number of phases |
Pressure-regulating section Regulating position |
Installation dimensions (mm) Install dimension (mm) |
Hole diameter on the box lid (ΦD, mm) Holes on tank cover ΦD(mm) |
||||
| H | H1 | ΦD2 | ΦD1 | Md | |||||||
| WSP Ⅱ,63/12-8×7 | 63 | 12, 24 | ±3×2.5% | 3 | Central region Middle par |
185 | 80 | 150 | 335 | M6 | Φ60 |
| WSP Ⅱ,125/12-8×7 | 125 | ±3×2.5% | 185 | 80 | 150 | 335 | M8 | ||||
| WSP Ⅱ,250/12-8×7 | 250 | ±3×2.5% | 185 | 80 | 150 | 340 | M8 | ||||
| WSP Ⅳ,63/12-3×2(Y-△ ) | 63 | /(Y-△ ) | (Y-△ ) | 150 | 75 | 88 | 170 | M6 | Φ43 | ||
| WSP Ⅳ,125/12-3×2(Y-△ ) | 125 | 150 | 75 | 88 | 175 | M8 | |||||
| WSP Ⅱ,63/40.5-4×3 | 63 | 40.5 | ±5% | Central region Middle part |
200 | 120 | 108 | 223 | M6 | ||
| WSP Ⅱ,125/40.5-4×3 | 125 | ±5% | 200 | 120 | 108 | 230 | M8 | ||||
| WSP Ⅱ,250/40.5-4×3 | 250 | ±5% | 200 | 120 | 108 | 250 | M8 | ||||
| WSP Ⅱ,63/40.5-6×5 | 63 | ±2×2.5% | 200 | 120 | 108 | 285 | M6 | ||||
| WSP Ⅱ,125/40.5-6×5 | 125 | ±2×2.5% | 200 | 120 | 108 | 295 | M8 | ||||
| WSP Ⅱ,250/40.5-6×5 | 250 | ±2×2.5% | 200 | 120 | 108 | 320 | M8 | ||||
| WSP Ⅲ,63/12-3×3 | 63 | 12 | ±5% | Neutral point Neutral point |
145 | 75 | 77 | 110 | M6 | ||
| WSP Ⅲ,125/12-3×3 | 125 | ±5% | 145 | 75 | 77 | 125 | M8 | ||||
| WSP Ⅲ,250/12-3×3 | 250 | ±5% | 165 | 90 | 108 | 168 | M8 | ||||
| WSP Ⅲ,400/12-3×3 | 400 | ±5% | 165 | 90 | 108 | 168 | M8 | ||||
| WSP Ⅲ,63/12-5×5 | 63 | ±2×2.5% | 156 | 78 | 88 | 163 | M6 | ||||
| WSP Ⅲ,125/12-5×5 | 125 | ±2×2.5% | 156 | 78 | 88 | 170 | M8 | ||||
| WSP Ⅲ,250/12-5×5 | 250 | ±2×2.5% | 160 | 86 | 108 | 220 | M8 | ||||
| WSP Ⅲ,63/40.5-3×3 | 63 | 40.5 | ±5% | 205 | 126 | 88 | 140 | M6 | |||
| WSP Ⅲ,125/40.5-3×3 | 125 | ±5% | 205 | 126 | 88 | 150 | M8 | ||||
| WSP Ⅲ,63/40.5-5×5 | 63 | ±2×2.5% | 205 | 130 | 88 | 195 | M6 | ||||
| WSP Ⅲ,125/40.5-5×5 | 125 | ±2×2.5% | 205 | 130 | 88 | 200 | M8 | ||||
| WSP Ⅵ,63/24-5×2 | 63 | 24 | series-parallel connection exchange | 180 | 105 | 108 | 250 | M6 | |||
| WSP Ⅵ,125/24-5×2 | 125 | 180 | 105 | 108 | 250 | M8 | |||||
Tap changers rated at 63 A are suitable for transformer tank covers with thicknesses of 5–8 mm (except for single-phase units); those rated at 125 A are suitable for covers 5–10 mm thick; and the 250 A and 400 A models are designed for covers 8–14 mm thick. The moving contact assemblies are available in clip‑type and roller‑type configurations—clip‑type units carry no designation, while roller‑type units must be specified at the time of order. We can also manufacture tap changers with extended mounting height to accommodate tank covers of greater thickness, as required by the customer. Please indicate any additional special requirements when placing your order.
The curent of 63A tap-changer is applicable to 5~8mm transformer cover (except single phase);The current of 125A tap-changer is applicable to 5~10mm transformer cover.The current of 250A and 400A tap-changers are applicable to 8~14mm transformer cover.The moving contact's structure is clamping type or roling type. The clamping type has no code number. If you need the rolling type, pleaseillustrate in ordering.
We can manufacture the tap-changer with raised highness beneath the cover in accordance with the customer's requirement.
If you have other specific requirements please detail it in ordering.
WSPIIl 3 Series No-Load Tap Changer (Disc Type) WSPIIl 3 Series de-energized Tap-changer (Tray form)
Type of tap-changer and installation size chart
| Switch model Type of tap-changer | Rated current (A) | Equipment highest voltage (kV) | Range of voltage regulation | Number of phases N0. | Regulating position | Installation dimension (mm) | Holes on tank cover ΦD(mm) | ||||
| H | H1 | ΦD2 | ΦD1 | Md | |||||||
| WSP III 3 63/12-3x3 | 63 | 12 | ± 5% | 3 | Middle part | 155 | 75 | 50 | 110 | M6 | Φ21 |
| WSP III 3 125/12-3x3 | 125 | 12 | ± 5% | 3 | Middle part | 155 | 75 | 50 | 125 | M8 | Φ21 |
WDPll 2 63/15-6x5QS Series No‑Excitation Tap Changer (Disc Type) WDPll 2 63/15-6x 5QS Series de-energized Tap-changer (Tray form)
WDPlI.63/-65 Series de-energized Tap-changer (Tray form) WDP ll, 63/-6x 5 Series de-energized Tap-changer (Tray form)
WDPIl,63/15-6x5QS2 Series off-circuit Tap Changer (Tray form)
Type of tap-changer and installation size chart
| Switch model Type of tap-changer |
Rated current (A) Rated current(A) |
Maximum Equipment Voltage (kV) Highest voltage for equipment (kV) |
Voltage regulation range Range of voltage regulation |
Number of phases N0.of phases |
Pressure-regulating section Regulating position |
Installation dimensions (mm) Install dimension (mm) |
Hole diameter on the box lid: ΦD (mm) Holes on tank cover ΦD(mm) |
|
| H | H1 | |||||||
| WDP II363/20-6×5 | 63 | 24 | ±2×2.5% | 1 | Central region Middle part |
82 | 75 | Φ34 |
| WDP II363/30-6×5 | 63 | 36 | ±2×2.5% | 1 | Central region Middle part |
102 | 95 | Φ34 |
Whole sealing (QMF)tray-form, linearity de-energized tap-changer
Fully sealed disc‑type and strip‑type no‑excitation tap changers are used in fully sealed oil‑immersed power transformers. In accordance with the requirements of fully sealed transformers, the sealing performance of the switch has been enhanced through a double‑seal design, ensuring leak‑free operation and thereby improving the overall performance of the transformer. The installation method and mounting dimensions of this switch are identical to those of conventional switches of the same model.
Type of tap-changer and installation size chart
| Switch model Type of tap-changer |
Rated Current (A) Rated current(A) |
Maximum Equipment Voltage (kV) Highest voltage for equipment (kV) |
Voltage regulation range Range of voltage regulation |
Number of phases Number of phases |
Pressure-regulating section Regulating position |
Installation dimensions (mm) Install dimension (mm) |
Hatch opening (mm) Holes on tank cover (mm) |
||||
| H | H1 | ΦD2 | ΦD1 | Md | |||||||
| WSP Ⅱ,63/12-4×3QMF | 63 | 12 | ±5% | 3 | Central region Middle part |
153 | 75 | 90 | 170 | M6 | Φ43 |
| WSP Ⅱ,125/12-4×3QMF | 125 | 175 | M8 | ||||||||
| WSP Ⅲ,63/12-3×3QMF | 63 | Neutral point Neutral point |
77 | 110 | M6 | ||||||
| WSP Ⅲ,125/12-3×3QMF | 125 | 125 | M8 | ||||||||
| WSP Ⅲ,63/12-5×5QMF | 63 | ±2×2.5% | 156 | 78 | 90 | 163 | M6 | ||||
| WSP Ⅲ,125/12-5×5QMF | 125 | 170 | M8 | ||||||||
Type of tap-changer and installation size chart
Switch model |
Rated Current (A) Rated current (A) |
Maximum Equipment Voltage (kV) Highest voltage for equipment (kV) |
Voltage regulation range Range of voltage regulation |
Number of phases Number of phases |
Pressure-regulating section Regulating position |
Installation dimensions (mm) Install dimension (mm) |
Hatch opening (mm) Holes on tank cover (mm) |
|||||||||
| H | H1 | H2 | L | L1 | L2 | L3 | L4 | I | Md | |||||||
| WST Ⅱ 63/12-4×3QMF | 63 | 12 | ±5% | 3 | Central region Middle part |
170 | 96 | 75 | 396 | 142 | 132 | 58 | 97 | 24 | M6 | Φ43 |
| WST Ⅱ 125/12-4×3QMF | 125 | 175 | 100 | 441 | 158 | 147 | 105 | 29 | M8 | |||||||
| WST Ⅲ 63/12-5×5QMF | 63 | ±2×2.5% | Neutral point Neutral point |
170 | 96 | 489 | 182 | 156 | 97 | 24 | M6 | |||||
| WST Ⅲ 125/12-5×5QMF | 125 | 175 | 100 | 628 | 232 | 201 | 105 | 29 | M8 | |||||||
| WST Ⅲ 250/12-5×5QMF | 250 | 110 | M10 | |||||||||||||
WSPII, tray-form tap changer for combined transformer used
This switch is a tap‑changing device for on‑load tap changers used in combined transformers. It is suitable for three‑phase pad‑mounted transformers with a maximum rated voltage of 12 kV or 40.5 kV and a rated current of 125 A or less. The tap changer must be operated only when the transformer is de‑energized.
Type of tap-changer and installation size chart
| Switch model Type of tap-changer |
Rated Current (A) Rated current(A) |
Maximum Equipment Voltage (kV) Highest voltage for equipment |
Pressure-regulating section Regulating position |
Voltage regulation range Range of voltage regulation |
H | H1 | H2 | Md | ΦD |
| WSP II 2 63/12-4 × 3 | 63 | 12 | Central region Middle part |
±5% | 292 | 117 | 70 | M6 | 120 |
| WSP II 2 63/12-6 × 5 | ±2 × 2.5% | M6 | |||||||
| WSP II 2 125/12-4 × 3 | 125 | ±5% | M8 | ||||||
| WSP II 2 125/12-6 × 5 | ±2 × 2.5% | M8 | |||||||
| WSP II 2 63/40.5-4 × 3 | 63 | 40.5 | ±5% | 407 | 133 | 120 | M6 | 120 | |
| WSP II 2 63/40.5-6 × 5 | ±2 × 2.5% | M6 | |||||||
| WSP II 2 125/40.5-4 × 3 | 125 | ±5% | M8 | ||||||
| WSP II 2 125/40.5-6 × 5 | ±2 × 2.5% | M8 |
WSPl2163~125/12~40.5-4x3~65 tray-type de-energized tap-changer WSP ll 21 63~125/12~40.5-4x 3~6 x 5 Tray-form de-energized tap-changer
| Switch model Type of tap-changer |
H | H1 | H2 | Md | Hatch opening Holes on tank cover |
| WSP II2163/12-4×3 | 312 | 114 | 70 | M6 | Φ43 |
| WSP II21125/12-4×3 | 312 | 114 | 70 | M8 | |
| WSP II2163/12-6×5 | 312 | 114 | 70 | M6 | |
| WSP II21125/12-6×5 | 312 | 114 | 70 | M8 | |
| WSP II2163/40.5-4×3 | 427 | 129 | 120 | M6 | |
| WSP II21125/40.5-4×3 | 427 | 129 | 120 | M8 | |
| WSP II2163/40.5-6×5 | 427 | 129 | 120 | M6 | |
| WSP II21125/40.5-6×5 | 427 | 129 | 120 | M8 |
WSPl,63~125/12~40.5-87 disc-type de-energized tap-changer WSP ll , 63~125/12~40.5-8x 7 Tray-form de-energized tap-changer
| Switch model Type of tap-changer |
H | H1 | H2 | Md | ϕ D |
| WSP II 2 63/12-8×7S | 308 | 114 | 70 | M6 | 145 |
| WSP II 2 125/12-8×7S | 308 | 114 | 70 | M8 | |
| WSP II 2 63/40.5-8×7S | 423 | 129 | 120 | M6 | |
| WSP II 2 125/40.5-8×7S | 423 | 129 | 120 | M8 |
WSPl,250/12-6x5SX disc-type de-energized tap-changer WSP ll ,250/12-6x 5SX Tray-form de-energized tap-changer
| Switch model Type of tap-changer |
H | H1 | H2 | Md | φD |
| WSP II 250/12-6×5SX | 349 | 133.5 | 70 | M8 | 166 |
WSPII2, 250/24-6x5 tray-type de-energized tap-changer WSP Il2 250/24-6 x 5 Tray-form de-energized tap-changer
| Switch model Type of tap-changer |
H | H1 | H2 | Md | ϕD |
| WSPⅡ2 250/24-6×5 | 449 | 153 | 100 | M8 | 195 |
Keywords:
Non-excited disc-type tap changer
Learn more about the product
Submit your request or feedback
If you are interested in our products, please feel free to contact us to discuss potential collaboration.
Telephone
Email box
Address
No. 3 Fengming Road, Hairun Subdistrict, Sanmen County, Taizhou City, Zhejiang Province
Website Development:China Enterprise Dynamics Nantong|Tag
Online Inquiry