Product Details
Rated voltage of 66 kV (maximum equipment voltage of 72.5 kV) and below, with a rated current of 2000 A and below.
This switch consists of an electric actuator, the switch body, and an electric controller. It is available in two configurations—vertical and horizontal (W)—and is suitable for oil-immersed furnace transformers with a maximum rated voltage of 72.5 kV or less and a rated current of 2000 A or less. Tap changing is performed under no‑excitation conditions and can be operated either electrically or manually.
Controller installation size:
Power-driven switch controller cable with 20 m
The tap-changer can be designed according to the user's request!
Circular (U) vertical electric de-energized tap-changer
Type of tap-changer and installation size chart
| Switch Type Type of changer |
Rated current (A) Rated current (A) |
Maximum Equipment Voltage (kV) Highest voltage for equipment (kV) |
Pressure-regulating section Regulating position |
Installation dimension (mm) | |||||||||||
| H3 | H2 | H1 | H | Md | Φd | Φd1 | Φd2 | Φd3 | Φd4 | n | |||||
| WSLD Ⅱ 200~630/12-4 × 3~10 × 9U4 | 200, 400, 630 | 12 | Central region Middle part |
120 | 187 | 580 | 860 | Md=M12 for a rated current of 200 A; Md=M16 for a rated current of 400 A; Md=M18 for a rated current of 630 A. | 370 | 380 | 425 | 460 | 380 | 18 | |
| WSLD Ⅲ 200~630/12-5 × 5~ 9 × 9U4 | Neutral point Neutral point |
||||||||||||||
| WSLD Ⅱ 200~630/40.5-4 × 3~10 × 9U4 | 40.5 | Central region Middle part |
170 | 240 | 780 | 1060 | |||||||||
| WSLD Ⅲ 200~630/40.5~5 × 5~9 × 9U4 | Neutral point Neutral point |
||||||||||||||
| WSLD Ⅱ 200~630/12-11 × 10~15 × 14U5 | 12 | Central region Middle part |
120 | 187 | 580 | 860 | 450 | 460 | 520 | 550 | 380 | 20 | |||
| WSLD Ⅲ 200~630/12-11 × 11~15 × 15U5 | Neutral point Neutral point |
||||||||||||||
| WSLD Ⅱ 200~630/40.5-11 × 10~15 × 14U5 | 40.5 | Central region Middle part |
170 | 240 | 780 | 1060 | |||||||||
| WSLD Ⅲ 200~630/40.5-11 × 11~15 × 15U5 | Neutral point Neutral point |
||||||||||||||
A model designation followed by “U5” indicates that the center-to-center diameter of the mounting holes on the cover of this circular tap changer is 520 mm.
The designation “U4” appended to the model number indicates that the center-to-center diameter of the mounting holes on the cover of this circular tap changer enclosure is 425 mm.
The model add-on U5 means the diameter of the cover's hole of this tap-changer is 520mm;
The model add-on U4 means the diameter of the cover 's hole of this tap-changer is 425mm.
Circular (U) and horizontal (W) de-energized tap-changer
Type of tap-changer and installation size chart AX
| Switch Type Type of changer |
Rated Current (A) Rated current(A) |
Maximum Equipment Voltage (kV) Highest voltage for equipment (kV) |
Pressure-regulating section Regulating position |
Installation dimension (mm) | ||||||
| L1 | L2 | L3 | L4 | H1 | H2 | Md | ||||
| WSLD Ⅱ 200~630/12-4×3~8×7WU4 | 200, 400, 630 | 12 | Central region Middle part |
120 | 140 | 544 | 620 | 150 | 355 | The current is 400 A, and Md = M12. The rated current is 630 A, and the model is Md=M16. |
| WSLD Ⅲ 200~630/12-3×3~7×7WU4 | Neutral point Neutral point |
|||||||||
| WSLD Ⅱ 200~630/40.5-4×3~8×7WU4 | 40.5 | Central region Middle part |
170 | 190 | 744 | 820 | ||||
| WSLD Ⅲ 200~630/40.5--3×3~7×7WU4 | Neutral point Neutral point |
|||||||||
Keywords:
Electric non-excitation tap changer
Learn more about the product
Submit your request or feedback
If you are interested in our products, please feel free to contact us to discuss potential collaboration.
Telephone
Email box
Address
No. 3 Fengming Road, Hairun Subdistrict, Sanmen County, Taizhou City, Zhejiang Province
Website Development:China Enterprise Dynamics Nantong|Tag
Online Inquiry